SERVICE MANUAL TNC 306/360

Page 51

HEIDENHAIN Service

RANGE EXCEEDED

- The range has been exceeded during scanning, i.e. a part of the contour is outside

the range.

CYCL-PARAMETER INCORRECT

- The programmed travel or the distance between lines or points is negative or

> 56 535 mm (only possible with Q-parameter programming).

TOUCH POINT INACCESSIBLE

- The stylus was deflected before the range was reached during approach.
- In the cycle CONTOUR LINES, the stylus was not deflected within the range.

STYLUS ALREADY IN CONTACT

- The stylus is not at rest, although it is not touching the contour.

PLANE WRONGLY DEFINED

- One of the coordinates of the starting point in the cycle CONTOUR LINES is identi-

cal to the touch probe axis.

START POSITION INCORRECT

- The coordinate of the starting point that is identical to the starting probe axis, is beyond

the defined range.

AXIS DOUBLE PROGRAMMED

- The same axis has been programmed for both starting point coordinates in the cycle

CONTOUR LINES.

TIME LIMIT EXCEEDED

- In the scanning cycle CONTOUR LINES the first point of the scanned line was not

reached within the programmed time limit.