beautypg.com

X23 = tnc operating panel (te), 4 pin layout: plc board – HEIDENHAIN TNC 306 Service Manual User Manual

Page 21

background image

SERVICE MANUAL TNC 306/360

Page 17

HEIDENHAIN Service

X11 Electronic Handwheel HR 130/HR 330

X12 Touch Probe System TS 120 (TS
111/TS 511, only via adaptor cable

Flange socket with female insert (9-pin)

Flange socket with female insert (15-pin)

Pin No.

Signal Designation

Pin No.

Signal Designation

1,3,5,7,9

do not assign

1

internal shield

2

GND (0V)

3

ready for operation

4

+ 12 V

4

start

6

DTR

5

+ 15 V

8

RxD

6

+ 5V (Up)

Housing

external shield

7

-battery warning

8

0 V (Un)

9

trigger signal

10

-trigger signal1)

2, 11 to 15

not assigned

1) Stylus at rest = high level

6.1.4 Pin Layout: PLC Board

X44 Power Supply (PLC part)
Terminal block (pluggable) 3-pin

Pin No.

Assignment

1

+ 24 V_A can be switched off with EMERCENCY STOP

2

+ 24 V cannot be switched off with EMERGENCY STOP

3

0 V

X23 TNC Operating Panel (TE)
Flange socket with female insert (37-pin)

Pin No.

Assignment

1

RL0

20

SL0

2

RL1

21

SL1

3

RL2

22

SL2

4

RL3

for key

23

SL3

for key

5

RL4

matrix

24

SL4

matrix

6

RL5

25

SL5

7

RL6

26

SL6

8

RL7

27

SL7

9

do not assign

28

do not assign

10

do not assign

29

do not assign

11

do not assign

30

do not assign (internally on 0 V)

12

do not assign

31

do not assign

13

do not assign

32

do not assign

14

do not assign

33

do not assign

15

do not assign

34

spindel override (wiper)

16

do not assign

35

feed override (wiper)

17

do not assign

36

+ 5 V override potentiometer

18

do not assign

37

0 V override potentiometer

19

do not assign

housing

external shield

This manual is related to the following products: