14.6.2 Error Messages during Data Transfer via the

RS-232C Interface

TRANSFERRED VALUE ERRONEOUS X

X = A Faulty character frame

B Character overflow
C Faulty character frame or character overflow
D Parity error
E Faulty character frame or parity error
F Character overflow or parity error
G Faulty character frame or character overflow or parity error
H Overflow of receiveing buffer
M Control has received the character for "negative acknowledgement" (NAK)
more than 3 times
N Control has sent the character for "negative acknowledgement" (NAK)
more than 3 times

EXT. INPUT/OUTPUT NOT READY

-

DSR signal missing at the TNC

-

FE not connected

-

Defective or wrong transfer cable

WRONG PROGRAM DATA

Wrong program data have been detected during data transfer.

ENTRY VALUE INCORRECT

-

The control requires more machine parameters than are stored on the external data
medium.

-

One or more machine parameters on the external data medium have non-permissible
values.