1 overview – HEIDENHAIN TNC 306 Service Manual User Manual
Page 55

SERVICE MANUAL TNC 306/360
Page 48
HEIDENHAIN Service
12. Handwheel HR 130/330
12.1 Overview
HR 130
Id.No. 254 040 --
HR 130.001
Id.No. 249 371 --
HR 330
Id.No. 251 534 --
Cable adaptor for HR 330
Id.No. 249 889 --
12.2 Checking the Handwheel HR 130/330
12.3 Error Messages
HANDWHEEL?
The data transfer (cable) has been interrupted.
HANDWHEEL DEFECTIVE
The light unit in the electronic handwheel is not emitting enough light, with the result that
the signals in the handwheel are too small. An error signal is sent over the serial interface
of the handwheel.
Pin
Color
Signal
1
2
3
4
5
6
bl
bl
gn
ye
br
wh
EM.
STOP
RxD
DTR
+12V
0V
Pin
Color
Signal
1
4
6
8
wh
br
ye
gn
0V
+12V
DTR
RxD
The serial handwheels HR 130 and HR
330 can only be tested with an
oscilloscope. The control signals (X11
PIN6 = DTR, PIN8 = RxD) must
correspond to the diagram at the left.
The supply voltage for the handwheel
is fed via the logic unit (X11, PIN2
= 0V, PIN4 = + 12V).
t = 6 ms