beautypg.com

1 overview – HEIDENHAIN TNC 306 Service Manual User Manual

Page 55

background image

SERVICE MANUAL TNC 306/360

Page 48

HEIDENHAIN Service

12. Handwheel HR 130/330

12.1 Overview

HR 130

Id.No. 254 040 --

HR 130.001

Id.No. 249 371 --

HR 330
Id.No. 251 534 --

Cable adaptor for HR 330
Id.No. 249 889 --

12.2 Checking the Handwheel HR 130/330

12.3 Error Messages

HANDWHEEL?

The data transfer (cable) has been interrupted.

HANDWHEEL DEFECTIVE

The light unit in the electronic handwheel is not emitting enough light, with the result that
the signals in the handwheel are too small. An error signal is sent over the serial interface
of the handwheel.

Pin

Color

Signal

1
2
3
4
5
6

bl
bl

gn
ye

br

wh

EM.
STOP
RxD
DTR
+12V
0V

Pin

Color

Signal

1
4
6
8

wh

br

ye
gn

0V
+12V
DTR
RxD

The serial handwheels HR 130 and HR
330 can only be tested with an
oscilloscope. The control signals (X11
PIN6 = DTR, PIN8 = RxD) must
correspond to the diagram at the left.
The supply voltage for the handwheel
is fed via the logic unit (X11, PIN2
= 0V, PIN4 = + 12V).

t = 6 ms

This manual is related to the following products: