SERVICE MANUAL TNC 306/360
Page 29
HEIDENHAIN Service
8.2 Power Supply of the Visual Display Units
The BE 212 screen is supplied with a D.C. voltage of +12V via connector X1, flange socket
with male insert (15-pin).
The BF 110 flat screen is supplied via the 2-pin terminal block X1.
X1
X2
+
-
X1: Power Supply
Pin No.
Assignment
1
+ 12 V 1)
2
0V
Pin No.
Signal
1 and 8
0V supply
2 and 4
+ 12 V supply
3,5,6,7
not assigned
9
V SYNC
10
H SYNC
11
not assigned
12
0V signal
13
VIDEO
14,15
not assigned
housing
external shield=housing
X1: Connection to LOGIC UNIT
Flange socket with male insert (15-pin)