SERVICE MANUAL TNC 306/360
Page 7

HEIDENHAIN Service

Screen Display (blinking error message)

Error Cause

PROCESSOR CHECK ERROR X

X = 0

1
2
3
4
5
6
7
8

A
B
C
D
E

F

H
L
M
P
R

CRC sum control data incorrect
CRC sum machine parameter incorrect
Check sum of NC memory incorrect
Test plane incomplete
Crosstalk between data bits in the RAM
Crosstalk between addresses in the RAM
Stack overflow
CRC sum PLC program ASCII
CRC sum PLC program Opcode

Software error main processor
Software error display task
Time slice overflow
Command stack overflow control loop
Wrong command MAIN PROCESSOR
TASK

CONTROL LOOP TASK

Wrong display mode MAIN PROCESSIR
TASK

DISPLAY TASK

Control loop: "counter not latched"
Wrong control loop command
Operating voltage out of tolerance
Disabled software function is activated
PLC Positioning, datum shift (PLC), spindle
orientation or limit switch
shift active with MP7440 bit 2 = 1 or
MP3030 = 1

If the error message "PROCESSOR CHECK ERROR XX" (X= identification letter, see
above!) comes up repeatedly, please return the complete logic unit to HEIDENHAIN for
repair. Indicate also the error message and the identification letters.