Major error messages and their causes – HEIDENHAIN TNC 306 Service Manual User Manual
Page 8
SERVICE MANUAL TNC 306/360
Page 6
HEIDENHAIN Service
3. Major Error Messages and their Causes
The integrated monitoring system distinguishes between minor and major errors; major
error messages (e.g. malfunctions of the encoders, of the drives or data processing errors)
blink. In the case of gross errors, the control opens the contact "Control Ready for
Operation" which causes an emergency stop of the machine tool.
By switching off the main switch or pressing
END
, the "emergency stop" state can be
reset, provided that the error cause has been eliminated.
Screen Display (blinking error message)
Error Cause
PROCESSOR CHECK ERROR XX
XX = 08
0C
10
14
18
20
24
28
2C
30
34
38
3C
40
44
48
4C
50
54
58
5C
60
64-7C
94-BC
Bus error
Address errror
Illegal instruction
Division by 0
Error output for CHK command
(check range)
Error output for TRAPV command
(trap on overflow)
Privilege infringement (supervisor
command in the user-mode)
Emulator trap
Emulator trap
-
-
-
Interrupt vector not initialized
Interrupt vector not initialized
Interrupt vector not initialized
Interrupt vector not initialized
-
-
-
-
-
False interrupt (interrupt with priority
0)
Interrupt autovector 4-7, user
Interrupt. $100-$3FC
-
If the error message "PROCESSOR CHECK ERROR XX" (XX = identification letters,
see above) comes up repeatedly, please return the complete logic unit to HEIDENHAIN
for repair. Indicate also the error message and the identification letters.
Notes