beautypg.com

Major error messages and their causes – HEIDENHAIN TNC 306 Service Manual User Manual

Page 8

background image

SERVICE MANUAL TNC 306/360
Page 6

HEIDENHAIN Service

3. Major Error Messages and their Causes

The integrated monitoring system distinguishes between minor and major errors; major
error messages (e.g. malfunctions of the encoders, of the drives or data processing errors)
blink. In the case of gross errors, the control opens the contact "Control Ready for
Operation"
which causes an emergency stop of the machine tool.

By switching off the main switch or pressing

END

, the "emergency stop" state can be

reset, provided that the error cause has been eliminated.

Screen Display (blinking error message)

Error Cause

PROCESSOR CHECK ERROR XX

XX = 08

0C
10
14
18

20

24

28
2C
30
34
38
3C
40
44
48
4C
50
54
58
5C
60

64-7C

94-BC

Bus error
Address errror
Illegal instruction
Division by 0
Error output for CHK command
(check range)
Error output for TRAPV command
(trap on overflow)
Privilege infringement (supervisor
command in the user-mode)
Emulator trap
Emulator trap
-
-
-
Interrupt vector not initialized
Interrupt vector not initialized
Interrupt vector not initialized
Interrupt vector not initialized
-
-
-
-
-
False interrupt (interrupt with priority
0)
Interrupt autovector 4-7, user
Interrupt. $100-$3FC
-

If the error message "PROCESSOR CHECK ERROR XX" (XX = identification letters,
see above) comes up repeatedly, please return the complete logic unit to HEIDENHAIN
for repair. Indicate also the error message and the identification letters.