beautypg.com

6 error messages, Err: 105, Err: 106 – HEIDENHAIN TNC 306 Service Manual User Manual

Page 64: Err: 107, Err: 108, Err: 001, Err: 002, Err: 003, Err: 004, Err: 010

background image

SERVICE MANUAL TNC 306/360

Page 57

HEIDENHAIN Service

14.6 Error Messages

14.6.1 Error Messages at the TNC in the FE-Mode

In this operating mode, the floppy disk unit outputs errors in the following format:

(SOH) ERR : (SP) (SP) (SP) XXX (ETB) (BCC)

The following errors can be displayed on the screen:

Input/output errors

ERR
ERR
ERR
ERR
ERR
ERR
ERR

001
002
003
004
005
006
007

Wrong command code
Illegal program name
Faulty data transfer
Program incomplete on disk
Overflow of receiving buffer
PRT interface selected more than once by the TNC
Data-buffer overflow

Errors during program write or read

ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR

010
011
012
013
014
015
016
017
018

Program not on disk
Program erase-protected
Program is being written to
Program directory is full
Disk is full
Text not found
Program name already exists
Disk access active
Program currently being read

Disk / drive / controller errors

ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR

100
101
102
103
104
105
106
107
108
109

Disk not initialized
Sector number too large 1)
Drive not ready 2)
Disk is write-protected
Faulty data on disk 1)
Sector cannot be found 1)
Check sum incorrect 1)
Disk controller defective 3)
DMA defective 3)
Disk exchanged during program loading

1) These error messages indicate that the disk is defective; in most cases, they can only be eliminated by reformatting the disk.
2) If this error message comes up while the disk is inserted, the drive is defective.
3) Hardware defect.

This manual is related to the following products: