SERVICE MANUAL TNC 306/360

Page 50

HEIDENHAIN Service

13.2 Error Messages

13.2.1 Error Messages during Probing

TOUCH POINT INACCESSIBLE

- After the start of a probing function, the scanning point was not reached within the
measuring range defined in the machine parameter 6130.

EXCHANGE TOUCH PROBE BATTERY

- The battery voltage of the touch probe system with infrared transmission is below the

minimum permissible value.

STYLUS ALREADY IN CONTACT

- The stylus was already deflected when the probing function was started.

PROBE SYSTEM NOT READY

- The infrared transmission between "Encoder" and "Transmitter/Receiver Unit"

is faulty (e.g. caused by contamination) or interrupted. The two windows of the touch
probe must be oriented to the transmitter/receiver unit.

- The battery is dead.

13.2.2 Error Messages during Digitizing of 3D-Contours

WRONG AXIS PROGRAMMED

- The touch probe axis in the scanning cycle RANGE is not identical to the calibrated

touch probe axis.

FAULTY RANGE DATA

- In the scanning cycle RANGE a MIN coordinate value is higher than or equal to the

corresponding MAX coordinate value.

- One or more coordinates are beyond the range determined by the software limit switches

in the scanning cycle RANGE.

- No scanning cycle RANGE is defined when calling the scanning cycles MEANDER or

CONTOUR LINES.

MIRRORING NOT PERMITTED

ROTATION NOT PERMITTED

SCALING FACTOR NOT PERMITTED

- Mirroring, rotation or scaling factor were active when the scanning cycles RANGE,

MEANDER or CONTOUR LINES were called.