Measuring with 3D Touch Probe
Function
MP
TNC
TNC
XNC
CNC
Input
AE-6
No.
Bit
2500 360
306
234
Input Value
Touch probe selection
6010*
I04
0 =
cable transmission
1 =
infrared transmission
0
Number of probing operations
6100
-
-
10
-
0, 1 = one probing operations
2 - 5 = number of probing operations
0
Maximum difference between several
probing operations
(message: PROBE VALUE INACCURATE)
6110
-
-
11
-
0 to 2 mm
0
Touch probe: feed for probing
6120*
80 to 30 000 [mm/min]
1000
Touch probe: measuring range
6130*
0.001 to 30 000.000 [mm]
20
Touch probe: set-up clearance
above the measuring point for
automatic measurement
6140*
I02
0.001 to 30 000.000 [mm]
20
Limitation of retraction for
MANUAL PROBING
6140*
-
-
11
-
0 to 19 999.999 [mm]
0 = stylus always retracted to starting pos.
0
Touch probe: Rapid traverse for
probing
6150*
80 to 30 000 [mm/min]
2000
Digitizing with 3D Touch Probe
Function
MP
TNC
TNC
XNC
CNC
Input
AE-6
No.
Bit
2500 360
306
234
Input Value
Oscillations in normal direction
6210**
-
03
-
03
0 to 65535 [s]
3
Feed in normal direction
6230**
-
03
-
03
0 to 1000 [mm/min]
30
Rated break point of stylus
6240**
-
03
-
03
0 to 10 [mm]
5
Modal M86
6250**
-
03
-
03
0 to 89
33
Output M90
6260**
-
03
-
03
0 = no
1 = yes
0
Output values rounded
6270**
-
03
-
03
0 = 1 µm
1 = 10 µm
0