SERVICE MANUAL TNC 306/360

Page 31

HEIDENHAIN Service

8.3.1 Power Supply for LE 360/C

8.3.2 Voltage Value Table

Measuring
Point on the
Power
Supply
Board

Reference
Point on the
Power
Supply
Board

Output

UNOM [V]

UMIN [V]

UMAX [V]

INOM [A]

LH 22

LH 20

LH 18

LH 14

LH 10

LH 2

LH1

LH24

LH 24

LH 24

LH 24

LH 24

LH4

LH3

+ 5V (UP)

+ 12V

+ 15V

- 15V

UBATT

+ 12V BE

+ 5V* 1 1)

+5.05

+ 12

+ 15.0

- 15.0

+ 4.5

+ 12.3

+ 5

+ 5.00

+ 11.4

+ 14.4

- 14.4

+ 3.9

+ 12

+4.75

+ 5.10

+ 12.6

+ 15.6

- 15.6

-

+ 12.6

+ 5.25

2.5

0.1

0.15

0.08

ca. 20 µA

1.3

0.3

1) potential-free
reset ULmax = 0.4V, UHmin = 3.9V