8. Power Supply

8.1 External Power Supply Requirements

The voltages must correspond to the following definitions:

Unit

Supply Voltage

Voltage Range
D.C. Average Value

Max. Current
Consumption

Power Consumption

NC

24V
(VDE 0551)

lower limit
20.4 V

LE 360: 1.2A to 1.5A

28.8W to 36W

LE

PLC

24 V

1.8A
if half of the inputs/
outputs are active
simultaneously

approx. 6W
if approx. 1/3 of the
inputs/outputs are active
simultaneously

PL 400

(VDE 0550)

upper limit
31 V

1)

21A
if half of the inputs/
outputs are active
simultaneously

approx. 25W
if approx. 1/3 of the
inputs/outputs are active
simultaneously

BF 110

0.85A with full utilization
of the VDU

approx. 20 W

8.1.1 NC Power Supply

The NC-part of the LE must not be connected to the control voltage of the machine tool! It requires its own
external power supply generated separately according to the German Standard VDE 0551:
D.C. voltage of 24 V with a permissible A.C. component (ripple voltage) of max. 1.5 Vpp (recommended
filtering capacitor 10000 µF/40 V-).

8.1.2 PLC Power Supply

The PLC part (PLC inputs and outputs) of the LE and the PL 400 is operated with a control voltage of 24 V (of
the machine tool), generated according to VDE 0550 (German standard).
Superimposed A.C. voltage components, arising from an non-controlled three-phase bridge connection with a
ripple factor of 5% (see German standard DIN 40110/10.75, section 1.2) are permissible. Thus, the highest
absolute value for the upper voltage limit is 32.6 V; the smallest absolute value for the lower voltage limit is
18.5 V.

The 0 V line of the PLC power supply must be
connected to the central signal ground of the
machine tool (ground line

> 6mm²)