beautypg.com

HEIDENHAIN TNC 306 Service Manual User Manual

Page 23

background image

SERVICE MANUAL TNC 306/360

Page 19

HEIDENHAIN Service

X25 Data Interface V.24/RS-232

X26 PLCI/O Board (PL)

Flange socket with female insert (25-pin)

Flange socket with male insert (25-pin)

Pin No.

Assignment

Pin No.

Assignment

1

shield

1, 2, 3

0 V * 1

2

RxD

4, 5, 6, 17, 18

not assigned

3

TxD

7

-RESET

4

CTS

8

-WRITE EXTERN

5

RTS

9

WRITE EXTERN

6

DTR

10

-A5

7

GND (0 V * 2)

11

-A3

8 bis 19

not assigned

12

-A1

20

DSR

13

shield

21 bis 25

not assigned

14, 15, 16

+ 12 V * 1

housing

external shield

19

serial IN 1

20

EMERGENCY STOP

21

-serial OUT

22

serial OUT

23

-A4

24

-A2

25

-A0

X27 Machine Operating Panel
Flange socket with female insert (37-pin)

Pin No.

Assignment

Pin No.

Assignment

1

I128

19

I146

2

I129

20

I147

3

I130

21

I148

4

I131

22

I149

5

I132

23

I150

6

I133

24

I151

7

I134

25

do not assign

8

I135

26

O01)

9

I136

27

O11)

10

I137

28

O21)

11

I138

29

O31)

12

I139

30

O41)

13

I140

31

O51)

14

I141

32

O61)

15

I142

33

O71)

16

I143

34

0 V (PLC) 2)

17

I144

35

0 V (PLC) 2)

18

I145

36

+ 24 V_A PLC 3)

37

+ 24 V_A PLC 3)

1) O0...O7 simultaneously to X21 (PLC output)

2) 0V PLC reference potential for testing

3) PLC voltage supply + 24V_A routed via fuse for

the inputs (can be switched off)

This manual is related to the following products: