background image

If you have included the file MOUSE.SYS in your

CONFIG.SYS file, repeat step 5 to modify the .SYS file as well.

Just substitute .SYS for .COM in the instructions.

When you are going to use the program with which you had the

mouse problem, you need to load the new mouse driver into the

computer’s memory. There are two ways to do this:

❏ Type the name of the new mouse driver at the MS-DOS

command prompt and then start the program.

❏ Modify your AUTOEXECBAT file (or another batch file)

to include the name of the new mouse driver. See your

MS-DOS Reference Manual for instructions.

Note

If you have already loaded the original mouse driver, reset the

computer before you load the new one.

Memory Module Problems

If you added extra memory to your system by installing SIMMs
and that memory is not operating properly, check the following:

1.

Check to make sure that you set the memory configuration
jumpers correctly and that they match your current SIMM

configuration. See Chapter 5 for instructions on setting

jumpers JP4 through JP8.

2.

If the jumpers are set correctly but the memory count

displayed by the power-on diagnostics program is incorrect,

you or your dealer may not have installed the SIMMs

correctly. They may be installed in the wrong sockets, they
may be the wrong type of SIMM, or they may not be

inserted all the way into their sockets. (Keep in mind that

the memory count does not include the 384KB of memory
between 640KB and 1MB.)

D-28 Troubleshooting