35
Loop through and E to E
SDA-00 E to E
SDA-00 models have an E to E path provided for monitoring purposes, as illustrated
in the following diagram.
When E to E mode is enabled, the play channel video and audio outputs are switched
to the corresponding record channel inputs when the play channel is in stop mode or
when no clip is loaded. The following table describes play channel operation
depending on the E to E selection.
If E to E mode is enabled, you can connect an external reference signal which is
synchronous to the video input. This eliminates artifacts on the play channel output
(periodic vertical shift) due to routing an asynchronous signal through the SDA-00 K2
Media Client. However, this is not required for recording, as the SDA-00 K2 Media
Client can record asynchronous signals.
NOTE: E to E is provided for monitoring the record channel, and is not intended
as a program switch.
E to E Setting
Play channel mode
Play channel output
Disabled
Play, FF, Rewind
Stop
Eject
Show clip
Show clip
Show black
Enabled
Play, FF, Rewind
Stop
Eject
Show clip
Show input
a.
Show input
a.
a.
Output is black if no video input is connected.
R1
Record
Channel 1
R2
Record
Channel 2
P2
Playd
Channel 2
P1
Play
Channel 1
P1
Output
Circuit
PB/EE Switch Path
PB/EE Switch Path
P2
Output
Circuit
R2
Input
Circuit
R1
Input
Circuit