Ac power specification, Environmental specifications – Grass Valley K2 Media Client System Guide v.3.3 User Manual
Page 188

188
K2 Media Client System Guide
June 9, 2009
Appendix B Specifications
AC power specification
The K2 Media Client specification is shown in the following table.
WARNING: Always use a grounded outlet to supply power to the
system. Always use a power cable with a grounded plug, such as the one
supplied with the system.
Environmental specifications
The K2 Media Client specification is shown in the following table.
Characteristic
Specification
Power supply
Dual, redundant
Mains Input Voltage
100V to 240V auto-range, 50-60Hz
Power consumption
300W typical, maximum AC current 6A @ 115VAC,
3A@230VAC
!
Characteristic
Specification
Ambient Temperature
Non-Operating
-40° to +60° C
Ambient Temperature
Operating
10° to +40° C
Relative Humidity
Operating 20% to 80% from -5 to +45 C
Non-Operating 10% to 80% from -30 to +60 C
Do not operate with visible moisture on the circuit boards
Operating Altitude
To 10,000 feet
IEC 950 compliant to 2000 meters
Storage Altitude
To 40,000 feet
Non-Operating
Mechanical Shock
Class 5 (30G) Thomson Grass Valley 001131500
Random Vibration
Operational: Class 6 Thomson Grass Valley 001131500
Non-Operational: Class 5 Thomson Grass Valley 001131500
Transportation
Thomson Grass Valley 001131500
Equipment Type
Information Technology
Equipment Class
Class 1
Installation Category
Category II Local level mains, appliances, portable equipment,
etc.
Pollution Degree
Level 2 operating environment, indoor use only.