beautypg.com

Powering up k2 raid – Grass Valley K2 Media Client System Guide v.3.3 User Manual

Page 155

background image

June 9, 2009

K2 Media Client System Guide

155

Powering up K2 RAID

19. In the left pane select

Device Manager

.

20. In the right pane open the

System devices

node and verify that

GVG ISCSI Multi-Path

Device Specific Module

is listed.

21. In Storage Utility, make a new file system

If you get a “…failed to remove the media database…” message, you can safely
proceed.

22. Restart the K2 client and log in to Windows.

23. Open AppCenter and manually remove all clips and bins except the default bin and

the recycle bin.

24. Uninstall and then reinstall both SNFS software and K2 Client software. Use the

sequence and detailed procedure in the K2 Release Notes for the version of K2
Client software currently on the K2 client.

25. As you install K2 Client software, when you arrive at the Specify Target Type

page, select

K2 with local storage

.

26. Restart the K2 client.

27. On a K2 Media Client, from the Windows desktop system tray, open SQL Server

Service Manager and verify that

Auto-start service when OS starts

is selected. (This

is not required on a K2 Media Client.)

The K2 client is now ready for record/play operations.

NOTE: If you ever unbind LUNs, you must do the above procedure again, starting
at step 5.

Powering up K2 RAID

To power up K2 RAID devices, do the following: