Layer 2 static aggregation configuration example – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 56
46
Task
Command
Remarks
Display the global or
group-specific link-aggregation
load sharing criteria.
display link-aggregation load-sharing mode
[ interface [ bridge-aggregation
interface-number ] ] [ | { begin | exclude |
include } regular-expression ]
Available in any view
Display detailed link aggregation
information for link aggregation
member ports.
display link-aggregation member-port
[ interface-list ] [ | { begin | exclude | include }
regular-expression ]
Available in any view
Display summary information
about all aggregation groups.
display link-aggregation summary [ | { begin |
exclude | include } regular-expression ]
Available in any view
Display detailed information about
a specific or all aggregation
groups.
display link-aggregation verbose
[ bridge-aggregation [ interface-number ] ] [ |
{ begin | exclude | include } regular-expression ]
Available in any view
Clear statistics for a specific or all
aggregate interfaces.
reset counters interface [ bridge-aggregation
[ interface-number ] ]
Available in user
view
Layer 2 static aggregation configuration example
In an aggregation group, only ports that have the same port attributes and class-two configurations (see
"
") as the reference port (see "
") can operate as Selected ports.
Make sure that all member ports have the same port attributes and class-two configurations as the
reference port. The other settings only need to be configured on the aggregate interface, not on the
member ports.
The configuration examples were created on a WX5004 access controller and may vary with device
to see where you configure Ethernet interfaces.
Table 7 Ethernet interface configuration prerequisites
Hardware
Ethernet interface configuration prerequisites
Access controller modules (installed in a switch)
LSQM1WCMB0
LSQM1WCMD0
LSBM1WCM2A0
LSRM1WCM2A1
LSRM1WCM3A1
You configure Ethernet interfaces on the switch.
NOTE:
To log in to the access controller module from the switch, use the oap connect
slot
slot-number
command.
LSWM1WCM10
LSWM1WCM20
You configure Ethernet interfaces on the switch.
NOTE:
To log in to the access controller module from the switch, use the oap connect
slot 1
slot-number
system
system-name
command.
Wireless switches
WX3024E
Use the oap connect slot 0 command on the access controller engine to log
in to the switching engine.
Access controllers
- H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module H3C WA3600 Series Access Points H3C WA2600 Series WLAN Access Points