Task

Command

Remarks

Display the global or
group-specific link-aggregation

load sharing criteria.

display link-aggregation load-sharing mode
[ interface [ bridge-aggregation
interface-number ] ] [ | { begin | exclude |

include } regular-expression ]

Available in any view

Display detailed link aggregation
information for link aggregation

member ports.

display link-aggregation member-port
[ interface-list ] [ | { begin | exclude | include }

regular-expression ]

Available in any view

Display summary information
about all aggregation groups.

display link-aggregation summary [ | { begin |
exclude | include } regular-expression ]

Available in any view

Display detailed information about
a specific or all aggregation

groups.

display link-aggregation verbose
[ bridge-aggregation [ interface-number ] ] [ |

{ begin | exclude | include } regular-expression ]

Available in any view

Clear statistics for a specific or all
aggregate interfaces.

reset counters interface [ bridge-aggregation
[ interface-number ] ]

Available in user
view

Layer 2 static aggregation configuration example

In an aggregation group, only ports that have the same port attributes and class-two configurations (see

"

Configuration classes

") as the reference port (see "

Reference port

") can operate as Selected ports.

Make sure that all member ports have the same port attributes and class-two configurations as the
reference port. The other settings only need to be configured on the aggregate interface, not on the

member ports.
The configuration examples were created on a WX5004 access controller and may vary with device

models.
Check

Table 7

to see where you configure Ethernet interfaces.

Table 7 Ethernet interface configuration prerequisites

Hardware

Ethernet interface configuration prerequisites

Access controller modules (installed in a switch)

LSQM1WCMB0
LSQM1WCMD0
LSBM1WCM2A0
LSRM1WCM2A1
LSRM1WCM3A1

You configure Ethernet interfaces on the switch.

NOTE:

To log in to the access controller module from the switch, use the oap connect

slot

slot-number

command.

LSWM1WCM10
LSWM1WCM20

You configure Ethernet interfaces on the switch.

NOTE:

To log in to the access controller module from the switch, use the oap connect

slot 1

slot-number

system

system-name

command.

Wireless switches

WX3024E

Use the oap connect slot 0 command on the access controller engine to log
in to the switching engine.

Access controllers