beautypg.com

Ensemble Designs BrightEye NXT 410 Clean HDMI Router User Manual

Page 98

background image

www.ensembledesigns.com

Page 98

BrightEye NXT 410/415/430 Compact Router Installation, Configuration and Operations Guide

Table 3

Desired automation Src
number

Src Name

Router port number

1

-

-

2

Server 6

Input Port 3

3

Server 4

Input Port 4

4

-

-

5

Studio 3

Input Port 2

6

-

-

7

Network Feed

Input Port 1

Table 4

Desired automation Dest
number

Dest name

Router port number

1

-

-

2

-

-

3

Transmitter

Output Port 2

4

-

-

5

-

-

6

-

-

7

-

-

8

Microwave

Output Port 1

Note:

In this example, we are assuming a protocol that numbers sources and destinations
beginning with the number 1. Some protocols begin numbering at zero (e.g., the
Grass Valley TEN-XL ASCII Protocol and the Generic ASCII protocol).

We can now use these lists to create a Profile in the BrightEye NXT Router that numbers the sources
and destinations to match the desired automation numbering scheme.

Using the BrightEye NXT’s Profile Editor to arrange the order of the sources and destinations in their
respective columns, and inserting spaces at the appropriate places, we can create a Profile with the
numbering order that the automation system requires. The Profile to accomplish this is illustrated in
Figure 1.