410 and 410-h default port configuration, 415 and 430 default port configuration – Ensemble Designs BrightEye NXT 410 Clean HDMI Router User Manual
Page 20

www.ensembledesigns.com
Page 20
BrightEye NXT 410/415/430 Compact Router Installation, Configuration and Operations Guide
410 and 410-H Default Port Configuration
Ports that are Unassigned, such as Port 3, can be configured from the front panel either as a Source or
Destination, as described on page 34. The two Clean Switches (CS) can be assigned to Destinations
as described on page 42.
In 1: Source
In 2: Source
I/O 3: Unassigned
Out 4: Destination
Out 5: Destination
In 6: Source
In 7: Source
In 8: Source
In 9: Source
Out 10: Destination
SFP I/O 11: Unassigned
SFP I/O 12: Unassigned
TSG 1: Source
TSG 2: Source
CS 1: Unassigned
CS 2: Unassigned
415 and 430 Default Port Configuration
The default port configurations for the BrightEye NXT 415 and 430 are shown below. Ports that are
Unassigned, such as Port 3, can be configured from the front panel either as a Source or Destination, as
described on page 34. The two Clean Switches (CS) can be assigned to Destinations as described on
page 42.
In 1: Source
In 2: Source
I/O 3: Unassigned
Out 4: Destination
Out 5: Destination
I/O 6: Unassigned
I/O 7: Unassigned
I/O 8: Unassigned
I/O 9: Unassigned
I/O 10: Unassigned
I/O 11: Unassigned
SFP I/O 12/13: Unassigned
SFP I/O 14/15: Unassigned
TSG 1: Source
TSG 2: Source
CS 1: Unassigned (430 only)
CS 2: Unassigned (430 only)
Default Port Configuration as Shipped from the Factory