Diagnostics screen, Diagnostics screen -56 – Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual
Page 88

3-56
W A N s u i t e 7 1 0 5
each non-zero Trap IP address. The SNMP Details screen (Figure 3.48) lets
you configure the SNMP parameters described in the paragraphs below.
Figure 3.48
SNMP Details Screen
Read Community
Accepts a character string identifying the group authorized to perform read
operations. The default setting is “Public.”
Write Community
Accepts a character string identifying the group authorized to perform write
operations. The default setting is “Private.”
Trap Community
Accepts a character string, which is included in SNMP traps generated by the
unit. The default setting is “Public.”
Trap IP Address
Accepts the IP address of a network device where alarm reporting traps are to
be sent.
Diagnostics Screen
The Diagnostics screen (Figure 3.49) provides a table for viewing the current
settings for the test and maintenance functions performed on the available
interfaces. This screen shows an upper-level view of all the interfaces so you
can see if any port is under test, and if so, view the results. You may change
diagnostic parameters on the Test Details screen, which is accessed by
clicking on the appropriate link on the Diagnostics screen. The properties of
the Diagnostics table are described in the paragraphs below.