SCADA Details Screen

Click on “SCADA” under the “Type” column on the Services screen to view
the SCADA Details screen (Figure 3.31). This menu gives you access to the
configuration parameters described in the paragraphs below.

Figure 3.31

SCADA Details Screen

Message Size

Maximum number of characters to buffer before sending a frame.

Values: 0

1024

Default: 256

Idle Character Delay

Maximum number of idle character time to wait before sending a frame.

Values: 0

65535

Default: 10

Input Terminator

Decimal value of the character that terminates a message before sending a
frame.

Values: 0

255

Default: 0

Data Direction

Data direction that the port will support. If set to “Input,” the port will only
accept incoming data and will not transmit data. If set to “Output,” the port
will ignore any incoming data. If set to “Both,” the port will process all data.

Values: Input, Output, Both
Default: Both

Clear Stats

Clears all Frame Relay statistics.

Pair Frame Relay
Statistics

Opens another Frame Relay Statistics screen that reverses the
service and the pair so you can view statistics for both sides of
the pair.