beautypg.com

Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual

Page 230

background image

4-96

W A N s u i t e 7 1 0 5

Tx High Utilization %

What the user considers Tx high utilization (expressed as a percentage) for
this service.

Values: 1

100

Default: 75

Tx High Threshold

(sec)

Number of seconds Tx high utilization must be present before an alarm
reports.

Values: 0

900

Default: 0 (Rx High Utilization Alarm Disabled)

Tx End of Day Low

Utilization %

What the user considers Tx low utilization at the end of the day for this
service.

Values: 0

100

Default: 0 (Tx Low Utilization Alarm Disabled)

HDLC Status and Alarm Table

Each second, HDLC utilization detectors will report transmit and receive
utilization to update the statistics displayed in the table at the center of the
screen. This table also gives the status of the alarms related to HDLC utilization.

The user-activated prompts listed below are at the bottom of the HDLC
Utilization Monitor Details screen.

Figure 4.91

HDLC Monitor 24 Hour History Screen

Prompt

Function

Clear Alarms

Clears all HDLC Monitor alarms.

HDLC 24 Hour
History

Displays HDLC monitor history in 15-min buckets for the
past 24 hours (Figure 4.91).

HDLC 30 Day History Displays HDLC monitor history in 24-hr buckets for the past

30 days (Figure 4.92).