S N M P A g e n t
B-9
ipadt1e1LOSSAlarmDeclared
25012
This trap is sent out when a Loss
of Signal Seconds alarm is
declared.
t1e1LOSSCount
ipadt1e1UASAlarmDeclared
25013
This trap is sent out when an
Unavailable Seconds alarm is
declared.
t1e1UASCount
ipadt1e1CSSAlarmDeclared
25014
This trap is sent out when a
Controlled Slip Seconds alarm is
declared.
t1e1CSSCount
ipadt1e1BPVSAlarmDeclared
25015
This trap is sent out when a
Bipolar Violation Seconds alarm
is declared.
t1e1BPVSCount
ipadt1e1OOFSAlarmDeclared
25016
This trap is sent out when an Out
of Frame Seconds alarm is
declared.
t1e1OOFSCount
ipadt1e1AISAlarmExists
25017
This trap is sent out when an
Alarm Indication Signal alarm is
declared.
t1e1AISCount
ipadt1e1RASAlarmExists
25018
This trap is sent out when a
Remote Alarm Signal alarm is
declared.
t1e1RASCount
ipadDLCIremoteSOSAlarm
25019
This trap is sent when the remote
unit for a DLCI senses and reports
an SOS condition.
ipadDLCIremoteEquipActive
ipadDdsLOSSAlarmDeclared
25020
This trap is sent out when a Loss
of Signal Seconds alarm is
declared.
ddsNetLOSCount
ipadDdsOOFSAlarmDeclared
25021
This trap is sent out when an Out
of Frame Seconds alarm is
declared.
ddsNetOOFCount
ipadDdsOOSSAlarmDeclared
25022
This trap is sent out when an Out
of Service Seconds alarm is
declared.
ddsNetOOSCount
ipadDdsFDLSAlarmDeclared
25023
This trap is sent out when a FDL
error Seconds alarm is declared.
ddsNetFDLCount
ipadDdsBPVSAlarmDeclared
25024
This trap is sent out when a
Bipolar Violation Seconds alarm
is declared.
ddsNetBPVCount
ipadDS0HighAlarmDeclared
25025
This trap is sent out when a high
utilization alarm is declared.
ipadDS0ConfigHighUtilCount
ipadDS0LowAlarmDeclared
25026
This trap is sent out when a low
utilization alarm is declared.
ipadDS0ConfigLowUtilAlarm
ipadHDLCRxHighAlarmDeclared
25027
This trap is sent out when a high
Rx utilization alarm is declared.
ipadHDLCConfigRxHighUtil
Count
ipadHDLCRxLowAlarmDeclared
25028
This trap is sent out when a low
Rx utilization alarm is declared.
ipadHDLCConfigRxLow
UtilAlarm