Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual
Page 49

W e b S e r v e r I n t e r f a c e
3-17
clock that is also supplied to the DTE as Transmit Clock. The “External”
option uses the external clock from the DTE.
Values: Internal, External
Default: Internal
NOTICE:
The “External” option is valid only in Packet Mode.
TX Invert Clock
Data is received from the customer’s equipment on the other clock edge.
Values: Disable, Enable
Default: Disable
NOTICE:
You will need to change this parameter if the propagation delay on the
serial cable causes data errors. This acts as a manual data aligner.
RX Invert Clock
(Applies to Serial 2
Screen Only)
The Rx Invert Clock parameter is only available for use in DTE Mode on the
Serial 2 port. Consequently, this configuration option should remain disabled
when configuring services for the Serial 1 port. Data is sent to the customer’s
equipment on the other clock edge.
Values: Disable, Enable
Default: Disable
Flow Control
Selects the type of flow control to be used if the port is asynchronous.
Values: None, Xon/Xoff, RTS/CTS
Default: None
Character Size
Selects the number of bits required to make up one asynchronous character.
Values: Five, Six, Seven, Eight
Default: Eight
Parity
Sets the parity bit if the port is asynchronous.
Values: None, Odd, Even
Default: None
Stop Bit
Selects the number of bits required to end the asynchronous character.
Values: 1, 2
Default: 1
RTS
The Request To Send parameter determines the source from which the unit
reads the RTS signal status. If set to “Normal,” the unit gets RTS from the
DTE on the Serial interface. If set to “Forced True,” RTS is always perceived
as “On.”
Values: Normal, Forced True
Default: Normal