Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual
Page 62

3-30
W A N s u i t e 7 1 0 5
Figure 3.28
Frame Relay Service Details Screen
Interface Type
If this service is connected to a Frame Relay network, the Interface Type
should be set to “UNI” because it is the user side of a user-to-Network
interface. If it is connected to a FRAD/router, the Interface Type should be set
to “NI” because it is the network side of a user-to-Network interface. If it is
connected to an equipment set for Network-to-Network interface, the Interface
Type should be set to “NNI.”
Values: UNI, NI, NNI
Default: UNI if interface is Network, NI if interface is Serial
Link Management
Set this parameter to the link management used by the equipment connected
to it. If set to “Auto,” the unit will learn the link management type and
display it on the status portion of this screen.
Once it discovers the link management type, set the unit to the discovered
value so that subsequent unit or network re-initialization will be faster.
Values: Auto, ANSI, CCITT, LMI, None
Default: ANSI
Max Frame Size
If Auto Diagnostic is set to “Yes,” the unit will discard received frames that
are larger than the maximum frame size. If Auto Diagnostic is set to “No,”
these large received frames will be sent, but will be counted in the Rx Invalid
statistics.
Values: 64–4096
Default: 2500
N1
This counter indicates the number of “keep alive” status inquiries sent
between full status requests.
Values: 5–255
Default: 5 if interface is Network (UNI), 6 if interface is Serial (NI).