beautypg.com

Appendix a specifications, Network 1, 2, and 3 interfaces, Serial interface(s) (data 1 and data 2) – Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual

Page 235: Appendix a, "specifications, Appendix a, specifications, Pecifications

background image

S p e c i f i c a t i o n s

A-1

A

P P E N D I X

A

A

PPENDIX

A

S

PECIFICATIONS

Network 1, 2, and 3 Interfaces

Line Rate:

1.544 Mbps (

±

50 bps)

Line Framing:

D4 or ESF

Line Code:

AMI or B8ZS

Input Signal (Long-haul): DS1, +1 to

27 dB (ALBO)

Connection:

RJ-48C jack, 100

(

±

5%)

Output Signal:

3.0 V (

±

10%) base -peak into 100

with protection

Mode:

Long-haul, Short-haul

DSX-1 Level (Short-haul): 0-110, 111-220, 221-330, 331-440, 441-550,

551-660,>661 ft

Line Build Out:

0,

7.5,

15,

22.5 dB attenuation

Transient Voltage:

1000 V protection, fused input / output

Jitter Control:

per TR 62411 and T1.403

Timing Source:

With “Function” parameter on Network 2 screen in

“Slaved” Mode, options are Internal, Network 1,
Network 2, Network 3, Serial 1, Serial 2

With “Function” parameter on Network 2 screen in

Network Mode, options are Internal, Network 1, Network
3, Serial 1

With “Function” parameter on Network 2 screen in APS

Backup Mode, options are Internal, Network 1, Network
3, Serial 1, Serial 2

Ones Density:

B8ZS, Nx 56 bit stuffing, alternate fill; complies with TR

62411

Note: Use Network 1 as the long-haul port and when terminating only one T1.

Serial Interface(s) (Data 1 and Data 2)

Connection: DB-25

female

DTE Ports:

Selectable EIA-530, EIA-530A, RS-232, or V.35