beautypg.com

D (figure 3.8) – Verilink WANsuite 7105 (34-00316.C) Product Manual User Manual

Page 44

background image

3-12

W A N s u i t e 7 1 0 5

CSES Switch Event

Indicates if an exceeded CSES threshold has caused a transfer to the standby
line.

Availability Timer

Minimum amount of time free of errors during active events that must expire
before this line is returned to service availability.

Values: 0

900 s

Default: 900 s

The Network APS screen provides the user-activated buttons described in the
table below.

Figure 3.8

Network APS 24-Hour History

Period

Period for which the APS 24 Hour History is displayed.

Timestamp

Time when the historical period was completed.

Occurrences

Number of times active line has been switched to standby line.

Duration

Number of seconds service was provided on this line.

Status

Displays the status of this line at the end of the period.

The APS 30 Day History screen and the Backup History screens include the
same parameters found on the APS 24 Hour History screen.

Performance screens for Network interfaces other than APS are shown below.

Button

Function

Submit

Sets any values that have been changed.

Clear Primary Events

Clears the primary line APS events and counts.

Clear Backup Events

Clears the backup line APS events and counts.

Primary History

Displays the primary line history of APS activity in 15-
minute buckets for the past 24 hours (Figure 3.8).

Backup History

Displays the backup line history of APS activity in 15-minute
buckets for the past 24 hours.