beautypg.com

10–internal settings, Sync page – Teac HS-2 User Manual

Page 93

background image

TASCAM HS-2

93

D-IN button:

Synchronize with the clock of the digital signal

selected as the input for DIGITAL IN.
You cannot select an input as the master clock if the

sampling rate converter is ON for that input.
On the second line of the button, the digital input

signal selected is shown.

NOTE

• A

mark appears on the button of the currently

active master clock.

• If synchronization from an external clock is interrupted,

the unit’s internal clock becomes active. In this case,

the

mark appears on the

INT

button to show that it

has become the active clock, and the

mark appears

on the button of the selected external clock that was

lost.

SYNC page

Make settings related to synchronization on this page.

NOTE

If the Option SY-2 has not been installed, the display is

shaded and the setting cannot be selected.

STATUS
Shows the status of the currently loaded project’s

sampling frequency and clock synchronization.

TC Chase
Use to turn playback synchronized with timecode

ON

or

OFF

(default).

Set it to

ON

when you want to match the timing of

this unit’s audio with a timecode master device (audio

recorder, video or built-in time code generator).

You can also set timecode offset (TC Offset) with the

timecode master device. Touch the

EDIT

button to

open the

CHASE Offset

screen where you can set the

offset value in a range between −

23:59:59.29

and

+

23:59:59.29

(default:

00:00:00.00

).

NOTE

TC Chase

can also be turned

ON

and

OFF

by pressing the

SHIFT and CALL keys at the same time.

TC Rechase
Turn this function, which re-synchronizes when synchro-

nization with timecode becomes inaccurate,

ON

or

OFF

(default).
When set to

OFF

, after synchronizing once, input time

code is ignored and the unit operates in free run mode.
When set to

ON

, set the amount of inaccuracy that triggers

rechasing.
To set the amount of inaccuracy that triggers rechase,

touch the knob and turn the DATA dial to select a value in

frames of

1/3

,

1

,

2

(default),

5

or

10

.

Master TC
Set whether the unit synchronizes with the built-in

timecode generator or with timecode input from another

device.

Internal button:
Synchronize with the built-in generator.
External button (default):
Synchronize with timecode input from another device.

10–Internal settings