Rs-232c connector, Rs-422 connector (attached to option sy-2 board), 2−names and functions of parts – Teac HS-2 User Manual
Page 16
16
TASCAM HS-2
When REMOTE Select (pin 14) is set to high, it can be used
as an ordinary parallel controller. When set to low, flash
start mode is enabled. In addition, depending on the
high/low setting of the Flash Page (pin 20), the key assign-
ments are as follows.
Pin 14
Pin 20
Flash start take
Low
High
1–10
Low
Low
11–20
The following example is of a connection that uses a fader
to start and stop playback of this device.
START
STOP
Pin 1 GND
PARALLEL
Pin 8
FADER START
For information about the assignment of AUX 1–3 (pins
17–19) functions, see “PARALLEL page” on page 96.
NOTE
When controlling this unit with an external device that is
connected to the PARALLEL connector, by simultaneously
asserting the PLAY and RECORD signals while this unit is
stopped, you can start recording immediately. In addition,
by simultaneously asserting the PLAY and RECORD signals
during playback in timeline mode, you can start
overwriting the recording.
RS-232C connector
The RS-232C connector on the rear panel can be
connected to an RS-232C connector on a computer to
allow control of this unit from that computer.
Make settings related to communication on the
RS–232C
page of the
REMOTE SETUP
screen. (See “RS–232C page”
on page 96.)
NOTE
Please contact TASCAM customer support for information
about this unit’s RS-232C command protocol.
RS-422 connector (Attached to Option SY-2
Board)
The Option SY-2 Board is equipped with the RS-422
connector.
You can control this unit remotely by installing the SY-2
Board to this unit and connecting the RS-422 connector
on its rear panel to a controller or editor compatible with
the SONY P2 protocol (RS-422).
Make settings related to operation on the
REMOTE SETUP
screen
RS–422
page. (See “RS–422 page” on page 96.)
NOTE
Please contact TASCAM customer support for information
about this unit’s protocol compatibility.
2−Names and functions of parts