Parallel connector, 2−names and functions of parts – Teac HS-2 User Manual
Page 15
TASCAM HS-2
15
.
WORD/VIDEO IN connectors
This BNC-type connector is for input of a word clock
signal (44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz,
192 kHz) or a video reference signal (NTSC/PAL black
burst signal, HDTV Tri-Level signal). Use the switch to
set whether or not to terminate with 75Ω.
/
WORD/VIDEO THRU/WORD OUT connectors
This BNC-type connector is for output of a word clock
signal (thru, 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4
kHz, 192 kHz) or a video reference signal (IN connector
signal thru only).
Use the THRU/WORD OUT switch to set the signal
output.
!
75Ω OFF/ON and THRU/WORD OUT switch
Use this switch to make the following settings.
• Whether or not the WORD/VIDEO IN connector has
a terminator (75Ω)
• The WORD/VIDEO output THRU/OUT setting (OUT
is only for WORD)
@
ETHERNET connector
Use this Ethernet connector to connect to a network
for file transfer and to control this unit from an external
source.
#
GROUND terminal
When using a TASCAM RC-HS20PD remote control
(sold separately), depending on the operating
environment, the color display might flicker or noise
might be heard when monitoring. If this occurs, use
the GROUND terminal. (Please prepare a wire to use
with the GROUND terminal.)
PARALLEL connector
The PARALLEL connector on the rear panel allows
external control of this unit. (TASCAM RC-SS20 can be
connected.) The pin assignments are as follows.
Pin No.
Normal
RC-SS20
PonMode
I/O
1
GND
GND
2
PLAY
FLASH 1
I
3
STOP
FLASH 2
I
4
RECORD
FLASH 3
I
5
SKIP FWD
FLASH 4
I
6
SKIP BWD
FLASH 5
I
7
(Reserved)
STOP
I
8
FADER_START
FADER_START
I
9
(Reserved)
(Reserved)
O
10
TALLY_PAUSE
TALLY_PAUSE
O
11
TALLY_RECORD
RESERVED
O
12
TALLY_STOP
TALLY_STOP
O
13
TALLY_PLAY
TALLY_PLAY
O
14
REMOTE_SELECT,
H or Open
REMOTE_SELECT, L
I
15
PAUSE
FLASH 6
I
16
(Reserved)
FLASH 7
I
17
AUX1, FF
FLASH 8
I
18
AUX2, REW
FLASH 9
I
19
AUX3, MARK
FLASH 10
I
20
(Reserved)
FLASH_PAGE
I
21
(Reserved)
(Reserved)
O
22
TALLY_SD
TALLY_SD*1
O
23
(Reserved)
(Reserved)
O
24
TALLY_CF
TALLY_CF*2
O
25
+5V*3
+5V*3
I: Command input for transport control
Internal circuit, +5V pull-up
Triggers from a low input level of 50 msec or more
O: Command output, for tally output
The internal circuit is open collector (10Ω output
impedance)
Output level low when asserted
20 V dielectric strength, 35 mA maximum current
*1 Assigned to CF indicators when connected RC-SS20
*2 Assigned to CD indicators when connected RC-SS20
*3 +5V: 50 mA maximum supplied current
2−Names and functions of parts