Version number, date and time stamp for the
requested firmware component.

PVT1B (Position, Velocity, and Time):
Provides: GPS Week number, GNSS satellites
used, latitude, longitude, navigation mode, and
DOP information.

PANICA Alert Text Message:
Details message receipt and processing.

Factory Default Settings

The COM1 Default Baud Rate = 57600 bps. The
output default messages on COM1 are as follows:

OK

– OnChange

??

– OnChange

PANICA

– OnChange

ALM1B

– OnChange

EPHEM1B

– OnChange

CHNLSTATUS1B

– 1 Hz

PVT1B

– 1 Hz

MEAS1B

– 1 Hz

Version

– every 600 seconds

PRODUCTINFO

– every 600 seconds

 NMEA Messages

The SF-3040 provides support both for selected
standard NMEA messages and for nonstandard
proprietary NMEA-type messages. These messages
must be scheduled by the user.