Factory default settings – NavCom SF-3040 Rev.F User Manual
Page 105

SF-3040 Product User Guide
– Rev. F
5-103
Version number, date and time stamp for the
requested firmware component.
PVT1B (Position, Velocity, and Time):
Provides: GPS Week number, GNSS satellites
used, latitude, longitude, navigation mode, and
DOP information.
PANICA Alert Text Message:
Details message receipt and processing.
Factory Default Settings
The COM1 Default Baud Rate = 57600 bps. The
output default messages on COM1 are as follows:
OK
– OnChange
??
– OnChange
PANICA
– OnChange
ALM1B
– OnChange
EPHEM1B
– OnChange
CHNLSTATUS1B
– 1 Hz
PVT1B
– 1 Hz
MEAS1B
– 1 Hz
Version
– every 600 seconds
PRODUCTINFO
– every 600 seconds
NMEA Messages
The SF-3040 provides support both for selected
standard NMEA messages and for nonstandard
proprietary NMEA-type messages. These messages