beautypg.com

Measurement Computing Data Acquisition Systems rev.10.4 User Manual

Page 298

background image

4.6-20 Daq API Command Reference

908594

Programmer’s

Manual


Option Type and Value Definitions Continued--DaqOptionType

WBK18 Options

(continued)

Option Type (optionType)

Description

Option Value

(optionValue)

Description

DcovWbk18HighPass0_1Hz

Sets the High Pass input filter
to 0.1Hz

DcovWbk18HighPass10Hz

Sets the High Pass input filter
to 10Hz

DcotWbk18HighPassCutOff

Configures the High
Pass input filter for
0.1Hz, 10Hz or DC
coupling

DcovWbk18HighPassDC

Sets the High Pass input filter
to DC coupling

DcovWbk18CurrentSrcOff

Turn current off

DcotWbk18CurrentSrc

Enables/disables
channel output current
to power ICP sensors –
active at acquisition
arming

DcovWbk18CurrentSrc4mA

Turn current on

DcovWbk18OverRangeOff

Disable

DcotWbk18OverRangeEnable

Enables/disables
channel over-range
detection for the
specified channel

DcovWbk18OverRangeOn

Enable

DcovWbk18CurrentSrcOff

Turn current off

DcotWbk18CurrentSrcImmediate

Enables/disables
channel output current
to power ICP sensors –
active immediately – for
the specified channel

DcovWbk18CurrentSrc4mA

Turn current on

DmotWbk18OverRangeLimit

Configure over-range
detection condition

1.0 to 100.0 (% of range)

Sets the level for the over-
range circuitry to detect an
over-range condition –
applies to all channels

DmotWbk18OverRangeEnable

Enables/disable over-
range detection for all
eight channels

0 to 255 (bit mask)

Each bit represents a channel.
Writing 255 enables all
channels

DmovWbk18esSine

Continuous sine wave output

DmotWbk18esMode

Configures the analog
output for continuous
sine or swept sine mode

DmovWbk18esSweptSine

Sweep through pre-set
frequency amplitude values

DmovWbk18esAmplitude10pp

10 volts p-p

DmovWbk18esAmplitude5pp

5 volts p-p

DmovWbk18esAmplitude2pp

2 volts p-p

DmovWbk18esAmplitude1pp

1 volt p-p

DmovWbk18esAmplitude0_5pp

0.5 volt p-p

DmovWbk18esAmplitude0_2pp

0.2 volt p-p

DmovWbk18esAmplitude0_1pp

0.1 volt p-p

DmotWbk18esAmplitude

Set the amplitude for
continuous or swept
modes

DmovWbk18esAmplitude0_0pp

0.0 volt p-p

DmotWbk18esFreq

Set the frequency for
continuous or swept
modes

1.0 to 5000 (Hz)

Specifies the output
frequency

DmovWbk18esRelayOpen

Specify relay open

DmotWbk18esRelay

Controls the output
relay

DmovWbk18esRelayClosed

Specify relay closed

DmotWbk18esFreqCycleTime

Swept mode buffer
cycle time. If total RAM
segments times the
duration time exceeds
the cycle time then
cycle time is ignored.

50 to 85699000 (microseconds)

Specify time in microseconds

DmotWbk18esFreqDurationTime

Specifies the duration a
frequency will be at the
output

50 to 85699000 (microseconds)

Specify time in microseconds