Measurement Computing Data Acquisition Systems rev.10.4 User Manual
Page 289

Programmer’s Manual
908594
Daq API Command Reference 4.6-11
Option Type and Value Definitions Continued--DaqOptionType
WBK14 Options
Option Type
(optionType)
Description
Option Value
(optionValue)
Description
DcovWbk14LowPassBypass
Bypass the Low Pass Filter
for the specified WBK14
channel
DcovWbk14LowPassOn
Turn on the Low Pass Filter
for the specified WBK14
channel
DcotWbk14LowPassMode
Turn on, bypass or set to
ext clock the Low Pass
Filter (LPF) on a WBK14
channel
DcovWbk14LowPassExtClk
Use External Clock to control
the cutoff frequency for the
Low Pass Filter for the
specified WBK14 channel
DcotWbk14LowPassCutOff
Set the Low Pass Filter
(LPF) cutoff frequency for
a WBK14 channel
1.0 to 100000.0 (Hz)
Set the Low Pass Filter
frequency (when LPF set to
DcovWbk14LowPassOn)
For the specified WBK14
channel
DcovWbk14HighPass0_1Hz
Set the High Pass Filter
(HPF) frequency to 0.1 Hz for
the specified WBK14 channel
DcotWbk14HighPassCutOff
Set the High Pass Filter
(HPF) cutoff frequency for
a WBK14 channel
DcovWbk14HighPass10Hz
Set the High Pass Filter
(HPF) frequency to 10.0 Hz
for the specified WBK14
channel
DcovWbk14CurrentSrcOff
Turn off the current source
for the specified WBK14
channel
DcovWbk14CurrentSrc2mA
Set the current source to 2mA
for the specified WBK14
channel
DcotWbk14CurrentSrc
Set the current source for
the WBK14 channel
DcovWbk14CurrentSrc4mA
Set the current source to 4mA
for the specified WBK14
channel
DcovWbk14PreFilterDefault
Use the built-in default 65 dB
pre-filter stage
DcotWbk14PreFilterMode
Set the pre-filter mode for
a WBK14 channel
DcovWbk12PreFilterOff
Turn the pre-filter off
DmovWbk14ExcSrcRandom
Use random signal waveform
generation for the excitation
waveform
DmotWbk14ExcSrcWaveform
Set the Excitation Source
waveform for a WBK14
DmovWbk14ExcSrcSine
Use Sine wave signal
waveform generation for the
excitation waveform
DmotWbk14ExcSrcFreq
Set the Excitation Source
frequency for a WBK14
1.0 to 550000.0 (Hz)
Sets the excitation source
waveform frequency
DmotWbk14ExcSrcAmplitude
Set the Excitation Source
amplitude for a WBK14
0.0 to 5.0 (Volts)
Sets the excitation source
waveform amplitude
DmotWbk14ExcSrcOffset
Set the Excitation Source
offset for a WBK14
-5.0 to 5.0 (Volts)
Sets the excitation source
signal offset
DmotWbk14ExcSrcApply
0.0 to 5.0 (Volts)
Apply excitation voltage
DcovWbk14FilterRange_1K
Sets the filter range for the
WBK14 channel to 1Khz
DcovWbk14FilterRange_5K
Sets the filter range for the
WBK14 channel to 5Khz
DcovWbk14FilterRange_10K
Sets the filter range for the
WBK14 channel to 10Khz
DcovWbk14FilterRange_15K
Sets the filter range for the
WBK14 channel to 15Khz
DcotWbk14ExtFilterRange
DcovWbk14FilterRange_20K
Sets the filter range for the
WBK14 channel to 20Khz