4.6-12 Daq API Command Reference

908594

Programmer’s

Manual


Option Type and Value Definitions -- DaqOptionType

WBK16 Options

Option Type

(optionType)

Description

Option Value

(optionValue)

Description

DcovWbk16ApplyFull

Selects Full Bridge

DcovWbk16ApplyHalfQtrPos

Selects Half-Bridge/
Quarter-Bridge

DcotWbk16Bridge

Selects the type of bridge
configuration.

For diagrams and related
text, refer to the
WaveBook User’s
Manual (p/n 481-0901).

DcovWbk16ApplyNone

normal reading, no shunt

DcovWbk16Apply120

Apply 120 ohm shunt – B
Shunts are not pre-installed.

DcovWbk16Apply350

Apply 350 ohm shunt – D
Shunts are not pre-installed.

DcovWbk16Apply1K

Apply 1 K ohm shunt – F
Shunts are not pre-installed.

DcotWbk16ShuntCal

Used to select the shunt
value for internal shunt-
calibration resistors. The
shunt resistors are not pre-
installed.

In regard to shunt setup,
refer to the WaveBook
User’s Manual
(p/n 481-0901).

DcovWbk16AutoZero

apply short (0 ohm)

DcotWbk16InDiag

Sets input diagnostics.

DcovWbk16ReadNone

Sets diagnostics for reading

input signals.

DcotWbk16OffsetDac

Sets the Dac Offset
relative to input.

0.0 to 4095.0 See Note 2.

See Note 2 at end of
WBK16 Table.

DcovWbk16Normal

Normal signal polarity.

DcovWbk16Inverted

Inverts signal polarity.

DcotWbk16Inv

Used to select normal

signal polarity, or to
invert the polarity, if
desired.

DcovWbk16FltBypass

Bypasses the filter

DcovWbk16Flt10Hz

Enables 10 Hz filter

DcovWbk16Flt1Khz

Enables 1 K Hz filter

DcotWbk16FilterType

Used to bypass the single-

pole low-pass filter
(LPF), or set it to one of
two cut-off frequencies:
10 Hz to reduce high
frequency noise; or
1K Hz for anti-aliasing &
slight noise rejection
while maintaining
moderate bandwidth.

DcovWbk16CoupleDC

Selects DC Coupling

DcovWbk16CoupleAC

Selects AC Coupling

DcotWbk16Couple

Sets the input coupling.

Use AC coupling to reject
unwanted DC offsets.
Use DC coupling when
both AC and DC
components are to be
presented to the
comparator as input.

DcovWbk16Bypassed

Bypasses SSH function

DcotWbk16Sample

Used to bypass or to

enable the WBK16’s
Simultaneous Sample and
Hold (SSH) function.

DcovWbk16Ssh

Enables the SSH function

(for WBK16 only)

DcovWbk16Exc0_0

Selects 0.0 V

DcovWbk16Exc0_5

Selects 0.5 V

DcovWbk16Exc1_0

Selects 1.0 V

DcovWbk16Exc2_0

Selects 2.0 V

DcovWbk16Exc5_0

Selects 5.0 V

DcotWbk16ExcDac

Used to select the

calibrated excitation DAC
values for WBK16.

DcovWbk16Exc10_0

Selects 10.0 V

DcovWbk16X1

Sets IAG gain to: x 1

DcovWbk16X10

Sets IAG gain to: x 10

DcovWbk16X100

Sets IAG gain to: x 100

DcovWbk16X1000

Sets IAG gain to: x 1000

DcotWbk16IAG

Provides gain definitions
for the WBK16 IAG
(Instrumentation
Amplifier Gain).

See Note 1 regarding
Voltage Out & Total
Gain.