Draco tera 42 – IHSE USA 480 Series Draco tera enterprise User Manual
Page 42

Draco tera
42
2013-08-14
You can select between the following traps:
Trap
Description
Status
Notification about the matrix status
Temperature
Notification about the temperature within the matrix
Insert Board
Notification about the insertion of a new I/O board
into a slot
Remove Board
Notification about the removal of an I/O board out of
a slot
Invalid Board
Notification about a non-properly working I/O board
Insert Extender
Notification about a newly connected extender to
the matrix, notification about a switched on
extender, notification about a newly established link
between extender and matrix
Remove Extender Notification about a removed extender from the
matrix, notification about a switched off extender,
notification about an interrupted link between
extender and matrix
Switch Command Notification about a performed switching operation
at the matrix
Fan Tray #1
Notification about the status of fan tray #1
Fan Tray #2
Notification about the status of fan tray #2
Power Supply #1
Notification about the status of power supply unit #1
Power Supply #2
Notification about the status of power supply unit #2
Power Supply #3
Notification about the status of power supply unit #3
For an activation of the SNMP agent function or the SNMP server
function, a restart of the matrix is obligatory.