beautypg.com

7 blank screen, 7 blank, Screen – IHSE USA 480 Series Draco tera enterprise User Manual

Page 200: Draco tera 200

background image

Draco tera

200

2013-08-14

Pos: 169 /806-IHSE/Hilfe im Problemfall/Bildausfall/480-xx @ 7\mod_1309944397665_6.doc @ 54058 @ 2 @ 1

9.7

Blank Screen

1

1

1

2

3

1 2

3

3

Rear View

Front View

Diagnosis

Possible Reason

Measure

Switching to a CPU Port
without active Source
(computer, CPU).

Switching to a CPU Port with an

active source (computer, CPU).

Monitors
remains dark
after switching
operation

Connection of a console
with a CON port or
connection of a CPU to a
CPU port not established
correctly.

Check connections regarding

CON and CPU ports at the
matrix.

LED 1 on or
LED 2 off

Connections CON unit,
matrix and CPU unit.

Check connecting cables and

connectors. (No cable, cable
break, CPU/CON unit offline,
CPU/CON unit connected to the
wrong port)

LED 3 off

Power supply

Check power supply units and

the connection to the power
network.