beautypg.com

Draco tera 138 – IHSE USA 480 Series Draco tera enterprise User Manual

Page 138

background image

Draco tera

138

2013-08-14

In order to configure the Multi-Screen Control, proceed as follows:

1. Select that block of 4 ports in the list of the working area which should

be configured for Multi-Screen Control.
There are only shown these blocks of 4 ports that contain at least one
CON Unit.

2. Activate the option Manual, if the USB-HID switching should only be

allowed by using keyboard commands (see Chapter 6.7, Page 173).
The manual switching allows the use of multi-head consoles.

3. Select in the field Arrangement the respective display arrangement

that is available at the CON Device you want to configure (1 x 4 or
2 x 2).
The fields for the configuration of the individual displays will be
arranged accordingly.

4. Select one or more control displays within the CON Device by setting

the function Control auf Y in the respective display field.
Control displays are referred to the extender units within the Multi-
Screen Control that are connected to keyboard and mouse.

5. When using the function Owner, you can determine which control

display is permitted for USB-HID switching to the different displays.
Select that display from the list.
In order to make a display accessible for all neighboring control
displays, set the function Owner to shared.

6. Use the function Frame to configure a red frame that shows the

current display with mouse control after the expiration of a selectable
timer.
The frame to fade in can be individually activated by using a timer
>0 seconds.


Pos: 80 /806-IHSE/Konfiguration/480_Speichern und Laden von Konfigurationen/480-xx/Speichern und Laden von Konfigurationen @ 7\mod_1309938757899_6.doc @ 53292 @ 2 @ 1