4 i/o port sdi, 5 power supply, 6 environmental conditions – IHSE USA 480 Series Draco tera enterprise User Manual
Page 190: I/o port sdi, 5 power, Supply, Draco tera 190

Draco tera
190
2013-08-14
7.4.4 I/O Port SDI
Pos: 149 /806-IHSE/Technische Daten/Pinbelegungen/Mini-BNC (SDI) @ 7\mod_1309943545633_6.doc @ 53930 @ @ 1
Mini BNC (SDI)
Picture
Pin
Signal
1
Data IN
1 2
2
GND
Pos: 150 /806-IHSE/Technische Daten/Stromversorgung/480-xx @ 7\mod_1309943583946_6.doc @ 53948 @ 2 @ 1
7.5
Power Supply
Nominal Current/Nominal Voltage
Draco tera 288
12 A, 100-240 V
ac
, 50/60 Hz
Draco tera 160
9 A, 100-240 V
ac
, 50/60 Hz
Draco tera 80, 48
5 A, 100-240 V
ac
, 50/60 Hz
Power Requirement
Draco tera 288
max. 202 W without I/O boards
Draco tera 160
max. 188 W without I/O boards
Draco tera 80
max. 99 W without I/O boards
Draco tera 48
max. 94 W without I/O boards
I/O Board
max. 13 W
Pos: 151 /806-IHSE/Technische Daten/Einsatzbedingungen/ATB_Einsatzbedingungen @ 5\mod_1278578980026_6.doc @ 42480 @ 2 @ 1
7.6
Environmental Conditions
Operating Temperature
41 to 113°F (5 to 45°C)
Storage Temperature
–13 to 140°F (–25 to 60°C)
Relative Humidity
Max. 80% non-condensing
Pos: 152 /806-IHSE/zz_Layout/Seitenumbruch @ 8\mod_1348581820516_0.doc @ 69462 @ @ 1