Comtech EF Data CDM-570 User Manual

Page 509

background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix L

MN/CDM570L.IOM

L–17

BUC Status

Use the drop-down menu to set the BUC PLL Alarm as Locked, Unlocked, or N/A. The
remaining values displayed in this section are read-only and cannot be changed.

Click [Submit] to save any changes made to this page.

L.5.2.2 Modem | LNB (Low-Noise Block Down Converter)

Use this page to configure Low-Noise Block Down Converter parameters, and display the LNB
status for L-Band operation.

Figure L-6. Modem | LNB page

LNB Configuration

• Use the drop-down menus to set the LNB DC Supply Voltage to Off, 13_Volts, 18_Volts,

or 24_Volts.

• Use the drop-down menus to set the LNB 10 MHz Reference to On or Off.
• Assign LNB Current Alarm Upper and Lower Limit values ranging from 0 to 600 mA.
• Assign LNB LO (Lockout) Frequency and designate the value as a HIGH (+) or LOW ()

limit.


The LNB Voltage and LNB Current values displayed in this section are read-only and cannot
be changed.

Click [Submit] to save any changes made to this page.