(ODU: Enable) 1:1 Æ Red-Box

Redundancy Box: Online
Mode Switches Voltages

Use the

◄ ►

arrow keys to select Online, Mode, Switches, or Voltages, and then press

ENTER.

(ODU: Enable) 1:1 Æ Redundancy Box Æ Online

Online Unit:

CSAT#1 CSAT#2 (◄ ►,ENT)

This display indicates the ODU currently online. The cursor will be flashing under
CSAT#1 or CSAT#2. If the need arises to change the Online unit, use the

◄ ►

arrow

keys to move the cursor position to the desired unit, and then press ENTER.

If the ODU Redundancy system is in AUTO mode, a ‘forced switch-over’
can only occurs if the currently Offline unit is fault-free.

(ODU: Enable) 1:1 Æ Redundancy Box Æ Mode

Operating Mode:

Manual Auto (◄ ►,ENT)

This display indicates the current operating mode of the 1:1 ODU system. The cursor
will be flashing under Manual or Auto. If the need arises to change the operating mode of
the 1:1 system, use the

◄ ►

arrow keys to move the cursor position to the desired

operating mode, and then press ENTER.

(ODU: Enable) 1:1 Æ Redundancy Box Æ Switches

Waveguide Switch Status:

Tx=OK Rx=OK (ENT or CLR)

This read-only screen shows status for both the Tx and Rx Waveguide Transfer Switches.
If either Switch reports an ambiguity from the commanded position, “OK” will change to
FT” to indicate a switch fault.

(ODU: Enable) 1:1 Æ Redundancy Box Æ Voltages

Redundancy Box Voltages:
5V= 5.0 12V=12.0 (ENT)

Provided to assist in troubleshooting system problems, this read-only display monitors
the voltages inside the Redundancy Controller Box.