beautypg.com

L.3.3.1.2.2 (config: odu (outdoor unit)) lnb – Comtech EF Data CDM-570 User Manual

Page 500

background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix L

MN/CDM570L.IOM

L–8

L.3.3.1.2.2 (CONFIG: ODU (Outdoor Unit)) LNB

LNB: DC-Voltage 10MHz
Alarm LO Mix (◄ ►, ENT)

Use the ◄ ► arrow keys to select DC-Voltage, 10MHz, Alarm, LO, or Mix, and then press
ENTER.

L.3.3.1.2.2.1 (CONFIG: ODU (Outdoor Unit)) LNB: DC-Voltage

LNB DC Supply Voltage:

13 volts (◄ ►,ENTER)

Use the ▲ ▼ arrow keys to select the value of the LNB DC power supply output voltage as 13
volts
, 18 volts, 24 volts, or Power OFF. Press ENTER when done.

L.3.3.1.2.2.2 (CONFIG: ODU (Outdoor Unit)) LNB: 10MHz

LNB 10MHz Reference:
On Off (◄ ►,ENTER)

Use the ◄ ► arrow keys to select the 10MHz frequency reference for the BUC as On or Off.
Press ENTER when done.

L.3.3.1.2.2.3 (CONFIG: ODU (Outdoor Unit)) LNB: Alarm

Set LNB Current Alarm:
Upper Lower (◄ ►,ENTER)

Use this menu to define the upper and lower limits of the LNB current ‘window.’ If the measured
LNB current falls outside this window, an alarm is generated.

Use the ◄ ► arrow keys to select Upper or Lower. Press ENTER when done.

(CONFIG: ODU (Outdoor Unit)) LNB: Set LNB Current Alarm Æ Upper

LNB Current Alarm Upper
Limit: 200mA (◄ ►,▲ ▼,ENT)

To edit the LNB Current Alarm Upper Limit: First, use the

◄ ►

arrow keys to select a digit

to edit, and then use the

▲ ▼

arrow keys to change the value of that digit. The valid range of

current is from 50 to 600 mA. Press ENTER when done.

This manual is related to the following products: