D.6.2 Receive (Rx) Commands and Queries

Rx Priority System = RFT (Highest priority), RMD, RCR, and RDR (Lowest Priority), indicated by shading. Any change to a higher
priority parameter can override any of the parameters of lower priority.

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Rx FEC Type

RFT=

1 byte,
value of 0 thru 6

Command or Query.
Rx FEC Type, where:
0=None (uncoded – no FEC) with differential encoding ON
1=Viterbi
2=Viterbi + Reed-Solomon
3= Reserved – do not use
4= Reserved – do not use
5=TCM + Reed-Solomon
6=Turbo
Example: RFT=1 (which is Viterbi only)

RFT=
RFT?
RFT*
RFT#
RFT+

RFT?

RFT=x
(same format
as command
argument)

Rx Demod type

RMD=

1 byte,
value of 0 thru 5

Command or Query.
Rx Demodulation, where:
0=BPSK
1=QPSK
2=OQPSK
3=8PSK
4=16QAM (Turbo or Viterbi + RS only)
5=8-QAM (Future option)
Depending on FEC type, not all of these selections will be valid.
All other codes are invalid.
Example: RMD=2 (selects OQPSK)

RMD=
RMD?
RMD*
RMD#
RMD+

RMD?

RMD=x
(see Description
of Arguments)