beautypg.com

L.5.2.1 modem | buc (block up converter), L.5.2 odu configuration pages – Comtech EF Data CDM-570 User Manual

Page 508

background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix L

MN/CDM570L.IOM

L–16

L.5.2 ODU Configuration Pages

When properly configured to operate with a BUC or LNB, the ‘Modem | BUC’ and ‘Modem |
LNB’
pages allow configuration of the operating parameters specific to the active unit.

Click the ‘Modem’ tab, and then click the ‘BUC’ or ‘LNB’ hyperlink to continue.

L.5.2.1 Modem | BUC (Block Up Converter)

Use this page to configure Block Up Converter parameters, and display the BUC status for L-Band
operation.

Figure L-5. Modem | BUC page

BUC Configuration

• Use the drop-down menus to set BUC RF Output, 10 MHz Reference, or DC Power

Control operations to Enable or Disable.

• Use the drop-down menu to select a BUC Address of 1 to 15.

• Assign the LO (Lockout) Frequency and designate the value as a HIGH (+) or LOW ()

limit.


• Assign BUC Current Alarm Upper and Lower Limit values ranging from 0 to 4000 mA.

This manual is related to the following products: