Comtech EF Data CDM-570 User Manual
Page 373
CDM-570/570L Satellite Modem with Optional IP Module
Revision 12
Appendix D
MN/CDM570L.IOM
D–23
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
Faults and
Status (cont.)
2, 6, and 8 are TBD (for future expansion)
c = Rx Traffic status:
0 = Rx Traffic OK
1 = Demodulator unlocked
3 = AGC Alarm - signal out of range
5 = RS Frame sync alarm
7 = EDMAC Frame sync alarm
A = Buffer Underflow
B = Buffer Overflow
D = Eb/No alarm
E = LNB Alarm (if attached)
F = AIS detected on incoming data
2, 4, 6, 8, 9, and C are TBD (for future expansion)
d = ODU status:
0=No ODU faults
1=BUC PLL
3=BUC current
5=BUC voltage
7=LNB current
9=LNB voltage
B=BUC temperature
D=BUC checksum
2, 4, 6, 8, A, and C are TBD (for future expansion)
Force Reboot
FRB=
None
Command only.
Force a hard reset of the unit in 5 seconds.
FRB=
FRB?
FRB*
FRB#
N/A
N/A
Force 1:1 Switch
FSW=
None
Command only.
This command takes no arguments. Forces the unit to toggle the Unit Fail relay to
the ‘fail’ state for approx 500ms. If the unit is a 1:1 pair, and it is currently the ‘On
Line’ unit, this will force a switchover, so the unit will then be in ‘Standby’ mode.
The command is always executed by the unit, regardless of whether it is stand-
alone, in a 1:1 pair, or part of a 1:N system.
FSW= (message
ok)
N/A
N/A