beautypg.com

Comtech EF Data CDM-570 User Manual

Page 373

background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–23

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Faults and
Status (cont.)

2, 6, and 8 are TBD (for future expansion)

c = Rx Traffic status:

0 = Rx Traffic OK
1 = Demodulator unlocked

3 = AGC Alarm - signal out of range
5 = RS Frame sync alarm
7 = EDMAC Frame sync alarm
A = Buffer Underflow
B = Buffer Overflow
D = Eb/No alarm
E = LNB Alarm (if attached)
F = AIS detected on incoming data

2, 4, 6, 8, 9, and C are TBD (for future expansion)

d = ODU status:

0=No ODU faults
1=BUC PLL
3=BUC current
5=BUC voltage
7=LNB current
9=LNB voltage
B=BUC temperature
D=BUC checksum
2, 4, 6, 8, A, and C are TBD (for future expansion)

Force Reboot

FRB=

None

Command only.
Force a hard reset of the unit in 5 seconds.

FRB=
FRB?
FRB*
FRB#

N/A

N/A

Force 1:1 Switch

FSW=

None

Command only.
This command takes no arguments. Forces the unit to toggle the Unit Fail relay to
the ‘fail’ state for approx 500ms. If the unit is a 1:1 pair, and it is currently the ‘On
Line’ unit, this will force a switchover, so the unit will then be in ‘Standby’ mode.
The command is always executed by the unit, regardless of whether it is stand-
alone, in a 1:1 pair, or part of a 1:N system.

FSW= (message
ok)

N/A

N/A