beautypg.com

Comtech EF Data CDM-570 User Manual

Page 383

background image

CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–33

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

BUC PLL Alarm

N/A 1

byte,

value of 0 or 1

Query only.
BUC PLL lock state, where:
1=Unlocked
0=Locked
If not available, response is 9.
Note: This command is only valid when the FSK and BUC power are turned On.
Example:
BPA=0 (BUC PLL is locked)

N/A

BPA?

BPA=x
(see Description of
Arguments)

BUC Power Control BPC= 1

byte,

value of 0 or 1

Command or Query – CDM-570L only.
0=Disable BUC DC Power
1=Enable BUC DC Power
Example: BPC=0 (BUC DC power disabled)

BPC=
BPC?
BPC*
BPC#

BPC?

BPC=x
(see Description of
Arguments)

BUC Software
Version

N/A

2 bytes

Query only.
Indicates the BUC software version, in the form xx.
If not available, response is 00
Note: This command is only valid when the FSK and BUC power are turned On.
Example: BSV=05 (Software version 05)

N/A

BSV?

BSV=xx
(see Description of
Arguments)

BUC Temperature N/A

3 bytes

Query only.
BUC temperature is returned, in the form sxx, where:
s = sign (+ or - character)
xx = value
If not available, response is –99
Note: This query is only valid when the FSK and BUC power are turned On.
Example:
BUT=-13 (BUC temperature is -13 degrees C)

N/A

BUT?

BUT=sxx
(see Description of
Arguments)

This manual is related to the following products: