CONFIG: Intfc (Interface)
Data Interface: RS422 IP
V.35 RS232 G.703(◄ ► ENT)
Use the
◄ ►
arrow keys to select RS422 (EIA-530), IP, V.35, RS232 (EIA-232), or G.703, and
then press ENTER.
5.2.2.1.7.1 (CONFIG: Interface) RS422 or V.35 or RS232
RTS/CTS Operation: (▲ ▼)
Loop,RTS Controls Tx Out
Selecting
RS422, V.35, or RS232 displays this typical submenu. Use the
▲ ▼
arrows keys to
select an option, and then press ENTER. Note the following:
Selection
Description
RTS/CTS Loop, No Action
RTS and CTS are looped, so that CTS echoes the state of RTS, but RTS
does not control the ON/OFF state of the carrier.
Loop, RTS Controls Tx Out
RTS and CTS are looped, so that CTS echoes the state of RTS, and RTS
controls the ON/OFF state of the carrier (in other words, the modem will not
bring up its TX carrier until RTS is asserted).
Ignore RTS, Assert CTS
RTS is ignored, and CTS is asserted unconditionally.
N/A - 1:N system in use
If the 1:N switch on the rear panel is active, then RTS/CTS are not supported;
the pins are assigned to redundancy functions.
5.2.2.1.7.2 (CONFIG: Interface) IP
If the optional IP Module is installed, and IP is selected, all of the CDM-570/570L rear panel
electrical interfaces are disabled, and all data for Tx and Rx is routed to and from the modem
board to the optional IP Module. The previous menu is then displayed.