CDM-570/570L Satellite Modem with Optional IP Module

Revision 12

Appendix D

MN/CDM570L.IOM

D–31

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Global
Configuration
(cont.)

R=RTS/CTS

Control

S = Statistics Sampling Interval
T = Attach BUC Alarm to Tx Alarm
U = Attach LNB Alarm to Rx Alarm
VVVVVV = expansion bytes

V = number of Tx channels for WAd

W = number of Rx channels for WAd

YYYY = expansion bytes

Fill unused expansion bytes with ‘x’

same as RTS
same as SSI
same as ABA
same as ALA

D.6.5 BUC Commands and Queries (CDM-570L ONLY)

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

BUC Address

BAD=

2 byte,
value of 01 to 15

Command or Query.
Indicates the BUC Address, in the form xx, where:
xx = between 01 and 15.
Example: BAD=03

BAD =
BAD?
BAD *
BAD #

BAD?

BAD=xx
(see Description of
Arguments)

BUC Comms
enable

BCE= 1

byte,

value of 0 or 1

Command or Query.
Enables or disables communications, via the FSK link, with an externally connected
Block Up Converter (BUC), where:
0=Disabled
1=Enabled
Example: BCE=0 (Disabled)

BCE=
BCE?
BCE*
BCE#

BCE?

BCE=x
(see Description of
Arguments)

BUC High Current
Limit

BCH=

4 bytes

Command or Query.
BUC High Current Limit, in mA, the form xxxx, where:
xxxx = between 500 and 4000
Example: BCH=3100

BCH=
BCH?
BCH*
BCH#

BCH?

BCH=xxxx
(see Description of
Arguments)