D.6.5 buc commands and queries (cdm-570l only) – Comtech EF Data CDM-570 User Manual
Page 381
CDM-570/570L Satellite Modem with Optional IP Module
Revision 12
Appendix D
MN/CDM570L.IOM
D–31
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Global
Configuration
(cont.)
R=RTS/CTS
Control
S = Statistics Sampling Interval
T = Attach BUC Alarm to Tx Alarm
U = Attach LNB Alarm to Rx Alarm
VVVVVV = expansion bytes
V = number of Tx channels for WAd
W = number of Rx channels for WAd
YYYY = expansion bytes
Fill unused expansion bytes with ‘x’
same as RTS
same as SSI
same as ABA
same as ALA
D.6.5 BUC Commands and Queries (CDM-570L ONLY)
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction Code
and Qualifier)
Response to
Query
BUC Address
BAD=
2 byte,
value of 01 to 15
Command or Query.
Indicates the BUC Address, in the form xx, where:
xx = between 01 and 15.
Example: BAD=03
BAD =
BAD?
BAD *
BAD #
BAD?
BAD=xx
(see Description of
Arguments)
BUC Comms
enable
BCE= 1
byte,
value of 0 or 1
Command or Query.
Enables or disables communications, via the FSK link, with an externally connected
Block Up Converter (BUC), where:
0=Disabled
1=Enabled
Example: BCE=0 (Disabled)
BCE=
BCE?
BCE*
BCE#
BCE?
BCE=x
(see Description of
Arguments)
BUC High Current
Limit
BCH=
4 bytes
Command or Query.
BUC High Current Limit, in mA, the form xxxx, where:
xxxx = between 500 and 4000
Example: BCH=3100
BCH=
BCH?
BCH*
BCH#
BCH?
BCH=xxxx
(see Description of
Arguments)