Introduction
MN/CDM570L.IOM
1–9
FAST System Theory
FAST allows an operator to order a unit precisely tailored for the initial application. When service
requirements change, FAST allows the operator to upgrade the topology of the unit on-location,
within minutes, and without having to remove the unit from the setup. This accelerated upgrade is
possible due to FAST’s extensive use of the programmable logic devices incorporated into Comtech
EF Data products.
FAST Implementation
Comtech EF Data’s FAST system is factory-implemented in the modem. All FAST options are
available through the basic platform unit at the time of order. FAST allows immediate activation
of available options – first, upon entry of the FAST Access Code through the front panel keypad,
and then by setting the desired operational parameters via the front panel, remote control, or Web
Server interfaces.
FAST and FAST-Accessible Hardware Options
Option
Description and Comments
Option
Installation
Method
Low Rate Variable
Data rate 2.4 kbps to 512 kbps
BASE UNIT
Mid-Rate Variable
Data rate 2.4 kbps to 2.048 Mbps
FAST
Full Rate Variable
Data rate 2.4 kbps to 5.0 Mbps
Extended Rate Variable
Data rate 2.4 kbps to 9.98 Mbps
8-PSK/8-QAM
Modulation Type
16-QAM Modulation
Type
R-S Codec
Closed-network Reed-Solomon Codec
HARDWARE
TPC Codec
5 Mbps Turbo Product Codec (IESS-315 compliant)
100W BPSU (CDM-570L only)
100 Watt@30
°C, 90 Watt@50°C, Internal 24V BUC PSU
150W BPSU (CDM-570L only)
150 Watt@50
°C, 180 Watt@30°C, Internal 48V BUC PSU
IP Module Ethernet Interface and IP Options
Option
Description and Comments
Option
Installation
Method
3xDES Data Encryption
Uses NIST certified 3x core
Firmware Version 1.4.0 and later
FAST
IP Header Compression
Firmware Version 1.4.0 and later
Payload Compression
Firmware Version 1.4.0 and later
Quality of Service (QoS)
Firmware Version 1.4.0 and later
IP Module Ethernet Interface
10/100 BaseT Ethernet interface: V1 (MPP-50) or V2 (MPP-70)
HARDWARE
Hardware options for basic modems can be ordered and installed either at the factory or in the
field. The operator can select options that can be activated easily in the field, depending on the