Troubleshooting:
Diagnostic LED Indications
To detect hardware, cabling, or configuration problems upon initialization of power, the RPC Series go
through a diagnostic sequence. To help determine the cause of the problem, the RPC Series have a CX
LED located on the front, right side of the unit. Upon initialization of power, refer to the table below
for interpretation.
INDICATION INTERPRETATION
Not lit
Normal unconnected operation
Brief flash followed by a solid illumination
Established connection on network port or
serial port
Flashes 1 time per cycle
Hardware or NIC problem
Flashes 2 times per cycle
Configuration error
Flashes 3 times per cycle
Cable or hub connection fault
Flashes 4 times per cycle
Duplicate IP address
Remains lit without a brief flash prior to
illumination
Memory error
NOTE: Diagnostic indications override a connection indication.